Essential Safety Measures List

The ultimate checklist to identify and manage the Essential Safety Measures in your building in Victoria, as required under Part 15 of the Building Regulations 2018, to ensure compliance and maintain safety for occupants and visitors.

In Victoria, building owners are legally responsible for maintaining the Essential Safety Measures (ESMs) installed in their buildings to ensure ongoing safety for occupants and visitors. These measures—such as fire detection systems, emergency lighting, fire doors, and exit signage—are critical to life safety and form part of the regulatory framework under Part 15 of the Building Regulations 2018. Regular inspection, testing, and maintenance of these systems is not optional; it is a legal obligation that directly affects building compliance and public safety.

This checklist is designed to help building owners identify which ESMs are present in their building and assess their ongoing maintenance responsibilities. It supports the creation and upkeep of an ESM maintenance schedule and can also be used to inform the annual essential safety measures report (AESMR). Reviewing this list and working with qualified professionals will help ensure compliance with relevant standards and avoid regulatory penalties.

  • Fire Fighting Services & Equipment
    • Automatic Fire Sprinkler Systems
      • Wet Pipe System, Dry Pipe System, Deluge & Water Spray System, Residential Sprinkler System
    • Fire Hydrant System, Booster Assembly & Valves
    • Fire Hose Reels System
    • Fire Water Pumps (Jockey, Jacking, Electric or Diesel Driven)
    • Water Storage Tanks for Fire Systems
    • Portable Fire Extinguishers
    • Fire Blanket
    • Fire Control Centre (or rooms)
    • Provisions for Special Hazards
    • Sprinkler Protection of Openings
  • Automatic Fire Detection & Alarm System
    • Including Heat Detectors, Smoke Detectors, Flame Detectors, Aspirating Smoke Detectors, Manual Call Points
    • Smoke and Heat Alarm System
    • Smoke and Heat Detection System
  • Occupant (Emergency) Warning Systems
    • Emergency Warning and Intercommunication System
    • Occupant Warning System
  • Special Hazards (Gaseous Fire Suppression) System
  • Means of Egress
    • Paths of travel to exits
    • Discharge from exits (including paths of travel from open spaces to the public roads to which they are connected)
    • Exits (including fire-isolated stairways and ramps, non- fire-isolated stairways and ramps, stair treads, balustrades and handrails associated with exits, and fire-isolated passageways)
  • Building Fire Integrity
    • Building elements required to satisfy prescribed fire-resistance levels.
    • Materials and assemblies required to have fire hazard properties
    • Elements required to be non-combustible, provide fire protection, compartmentation or separation
    • Wall-wetting sprinklers (including doors and windows required in conjunction with wall-wetting sprinklers)
    • Fire doors (including sliding fire doors and their associated warning systems) and associated self- closing, automatic closing and latching mechanisms
    • Solid core doors and associated self-closing, automatic closing and latching mechanisms
    • Fire Shutters
    • Fire windows/glazing (including windows that are automatic or permanently fixed in the closed position)
    • Fire protection at service penetrations through elements required to be fire-resisting with respect to integrity or insulation, or to have a resistance to the incipient spread of fire
    • Smoke doors and associated self-closing, automatic closing and latching mechanisms
    • Fire Protection associated with construction joints spaces and the like in and between buildings elements required to be fire-resisting with respect to integrity or insulation
    • Fire Curtains
  • Signs
    • Signs warning against the use of lifts in the event of fire
    • Warning signs on sliding fire doors and doors to non- required stairways, ramps and escalators
    • Signs, intercommunication systems, or alarm systems on doors of fire-isolated exits stating that re-entry to a storey is available
    • Signs alerting persons that operation of doors must not be impaired
    • Signs required on doors, in alpine areas, alerting people that they open inwards
    • Fire order notices required in alpine areas
  • Lighting
    • Emergency Lighting
    • Artificial Lighting required to assist occupant movement and egress
  • Air-Handling Systems
    • Smoke Hazard Management System: Automatic air pressurisation systems for fire- isolated exits
    • Smoke Hazard Management System: Zone Smoke Control System
    • Smoke Hazard Management System: Automatic Smoke Exhaust System
    • Smoke Hazard Management System: Automatic Smoke-and-Heat Vents
    • Carpark Mechanical Ventilation System
    • Atrium Smoke Control System
    • Smoke Hazard Management System: Air-handling systems that do not form part of smoke hazard management system and which may unduly contribute to the spread of smoke
    • Smoke Hazard Management System: Miscellaneous air-handling systems covered by Sections 5 and 11 of AS/NZS 1668.1 serving more than one fire compartment
    • Smoke Hazard Management System: Other Air-handling systems
  • Building Clearance & Fire Appliances
    • Building Clearance & Fire Appliances
    • Vehicular access around large isolated buildings
  • Building Use & Application
    • Classification and use of building
    • Occupancy hazard
  • Other Safety Measures
    • Glazed Assemblies
    • Balconies
    • Balustrades
    • Swimming Pool Safety Fencing
    • Refrigerated Chambers, Strong Rooms and Vaults
    • Bushfire Protection Measures
    • Passenger lift fire service controls
  • Emergency Power Supply