Automatic Fire Sprinkler System

Automatic Fire Sprinkler System

A fire sprinkler system also known as an automatic fire sprinkler system or fire (sprinkler) protection system is an active fire protection method comprising a water supply providing adequate water flow and pressure through a water distribution pipe network onto which fire sprinkler heads are connected.

An automatic fire sprinkler system typically comprises a series of individual components including;

  • Water Supply;
  • Pipe;
  • Stop Valve;
  • Alarm Valve;
  • Fire Sprinkler (head);
  • Alarm Test valve; 
  • Waste (drain down) valve;
  • Motorised alarm bell (also known as a gong).

In addition to this there may be additional components that support this arrangement including;

  • Valve Monitor;
  • Pressure Switch;
  • Flow Switch.

Types of Automatic Fire Sprinkler System

In Australia, the Australian Standard AS 2118 series defines various types of automatic fire sprinkler system;

  • General Systems1 (AS 2118.1)
    • Wet System; A system permanently charged with water both above and below the installation alarm valve (wet).
    • Alternate wet and dry system: A system that incorporates either a composite alarm valve, or a combination valve set comprising an alarm valve (wet) and an alarm valve (dry).
    • Pre-action System: A combination of a sprinkler system that is permanently charged with air or inert gas above the alarm valve and an independent fire detection system installed throughout the same area.
    • Recycling pre-action system: A system with heat detectors and incorporating pre- action flow control valve capable of repeated on/off cycles appropriate to the possible redevelopment of fire in the protected area.
    • Tail-end system: A system essentially similar to dry, alternate wet and dry, pre-action and deluge systems, with the limitation that it only forms an extension to the sprinkler system.
    • Tail-end anti-freeze system: A system essentially similar to wet systems with the limitation that it only forms an extension to the sprinkler system and contains anti- freeze solution.
  • Wall Wetting (AS 2118.2)
  • Drencher Systems (AS 2118.3)
  • Deluge Systems: A system of open sprinklers controlled by a quick-opening valve (deluge valve) that is operated by a system of a fire detection system or pilot sprinklers installed in the same areas as the open sprinklers
  • Sprinkler protection for accommodation buildings not exceeding four storeys in height (AS 2118.4)
  • Home fire sprinkler systems (AS 2118.5)
  • Combined sprinkler and hydrant systems in multistorey buildings (AS 2118.6)

In addition the National Construction Code also defines two additional automatic fire sprinkler system types for Type A construction;

  • FPAA101D - An automatic fire sprinkler system for Type A construction where the water supply is derived from drinking water;

  • FPAA101H - An automatic fire sprinkler system for Type A construction where the water supply is derived from thefirfe hydrant system water supply;

  • 1

    Australian Standard AS 2118.1-2017 - Clause 1.3.40 - Sprinkler System

    Disclaimer

    In preparing this definition, we have drawn from various sources including Legislation, Codes, Standards and industry information, research and knowledge.  Like the english language, these definitions may subtly change from time to time. As such these definitions are provided solely on the basis that users will be responsible for making their own assessment of the definition and and are advised to verify all relevant representations, statements and information.